Available from 0 sellers
No businesses are currently selling this product.
The 33 kV Outdoor Circuit Breaker is designed for high-voltage switching and protection applications in outdoor electrical substations. It helps control electrical circuits and interrupt current under specified operating and fault conditions, supporting reliable power distribution.
Featuring porcelain-clad construction and vacuum interruption technology, this circuit breaker is intended for outdoor substation environments. The catalog references IEC 62271-100 for design and type testing. Proper selection requires consideration of the system voltage, rated current, short-circuit breaking capacity, insulation requirements, and environmental conditions.
| Product Type | 33 kV Outdoor Circuit Breaker |
|---|---|
| Voltage Class | 33 kV |
| Installation | Outdoor Electrical Substation |
| Construction | Porcelain-Clad |
| Interruption Technology | Vacuum |
| Primary Function | High-Voltage Switching and Protection |
| Referenced Standard | IEC 62271-100 |
| Rated Current | Not Specified in Catalog |
| Breaking Capacity | Not Specified in Catalog |
The 33 kV Outdoor Circuit Breaker is designed to control and interrupt electrical circuits in high-voltage substation installations. It plays an important role in power distribution systems by helping isolate circuits during switching operations and specified electrical faults.
When integrated with suitable protective relays and control equipment, the circuit breaker can respond to fault signals and disconnect the affected circuit, helping protect electrical infrastructure.
The circuit breaker uses vacuum interrupter technology to interrupt electrical current within its rated operating limits. This technology is commonly used in high-voltage switching equipment because of its effective arc-interruption characteristics and suitability for repeated switching operations when properly maintained.
The porcelain-clad design is intended for outdoor substation environments. Equipment selection and installation should consider weather exposure, insulation coordination, electrical clearances, grounding, and site conditions to support safe and dependable operation.
The catalog references IEC 62271-100 for design and type testing. Before installation, the applicable compliance documentation and technical ratings should be verified. Rated current, breaking capacity, and insulation requirements must match the electrical system and its protection design.
Q1. What voltage class is specified?
The circuit breaker is designed for the 33 kV voltage class.
Q2. Where is this circuit breaker used?
It is intended for outdoor electrical substations, utility networks, and suitable industrial power installations.
Q3. Which interruption technology does it use?
The catalog specifies vacuum interrupter technology for electrical current interruption.
Q4. Which standard is referenced?
The catalog references IEC 62271-100 for design and type testing.
Q5. What is its rated breaking capacity?
The catalog does not provide a numerical breaking-capacity rating. Confirm the rated current and short-circuit breaking capacity from the manufacturer's technical documentation before purchase.
Be the first to ask a question about this product!