33 kV Outdoor Circuit Breaker

Brand: N/A

Price In Bangladesh

Available from 0 sellers

No businesses are currently selling this product.

The 33 kV Outdoor Circuit Breaker is designed for high-voltage switching and protection applications in outdoor electrical substations. It helps control electrical circuits and interrupt current under specified operating and fault conditions, supporting reliable power distribution.

Featuring porcelain-clad construction and vacuum interruption technology, this circuit breaker is intended for outdoor substation environments. The catalog references IEC 62271-100 for design and type testing. Proper selection requires consideration of the system voltage, rated current, short-circuit breaking capacity, insulation requirements, and environmental conditions.

Key Features

  • 33 kV high-voltage application
  • Outdoor substation installation
  • Porcelain-clad construction
  • Vacuum interrupter technology
  • High-voltage switching and fault interruption
  • Suitable for integration with protection systems
  • IEC 62271-100 standard reference

Specification

Product Type 33 kV Outdoor Circuit Breaker
Voltage Class 33 kV
Installation Outdoor Electrical Substation
Construction Porcelain-Clad
Interruption Technology Vacuum
Primary Function High-Voltage Switching and Protection
Referenced Standard IEC 62271-100
Rated Current Not Specified in Catalog
Breaking Capacity Not Specified in Catalog

Description

High-Voltage Switching and Protection

The 33 kV Outdoor Circuit Breaker is designed to control and interrupt electrical circuits in high-voltage substation installations. It plays an important role in power distribution systems by helping isolate circuits during switching operations and specified electrical faults.

When integrated with suitable protective relays and control equipment, the circuit breaker can respond to fault signals and disconnect the affected circuit, helping protect electrical infrastructure.

Vacuum Interruption Technology

The circuit breaker uses vacuum interrupter technology to interrupt electrical current within its rated operating limits. This technology is commonly used in high-voltage switching equipment because of its effective arc-interruption characteristics and suitability for repeated switching operations when properly maintained.

Porcelain-Clad Outdoor Construction

The porcelain-clad design is intended for outdoor substation environments. Equipment selection and installation should consider weather exposure, insulation coordination, electrical clearances, grounding, and site conditions to support safe and dependable operation.

Standards and System Compatibility

The catalog references IEC 62271-100 for design and type testing. Before installation, the applicable compliance documentation and technical ratings should be verified. Rated current, breaking capacity, and insulation requirements must match the electrical system and its protection design.

Why Choose This Product?

  • 33 kV Application: Designed for suitable high-voltage substation systems.
  • Vacuum Technology: Supports current interruption within specified operating limits.
  • Outdoor Construction: Porcelain-clad design intended for outdoor installations.
  • Protection Integration: Can operate with compatible protective relays and control systems.
  • Standards Reference: References IEC 62271-100 for design and type testing.

Applications

  • Outdoor electrical substations
  • Utility power distribution networks
  • Industrial power substations
  • High-voltage switching systems
  • Electrical protection installations
  • Power distribution infrastructure

Frequently Asked Questions (FAQ)

Q1. What voltage class is specified?
The circuit breaker is designed for the 33 kV voltage class.

Q2. Where is this circuit breaker used?
It is intended for outdoor electrical substations, utility networks, and suitable industrial power installations.

Q3. Which interruption technology does it use?
The catalog specifies vacuum interrupter technology for electrical current interruption.

Q4. Which standard is referenced?
The catalog references IEC 62271-100 for design and type testing.

Q5. What is its rated breaking capacity?
The catalog does not provide a numerical breaking-capacity rating. Confirm the rated current and short-circuit breaking capacity from the manufacturer's technical documentation before purchase.

 

No Reviews Yet
Login Required

Please login to write a review for this product.

Login to Review   Go to Review Page

Questions & Answers

No Questions Yet

Be the first to ask a question about this product!